Yayınlanmış 1 Ocak 2015 | Sürüm v1
Dergi makalesi Açık

The CCL-K11 ongoing key comparison. Final report for the year 2013

  • 1. BEV, Arltgasse 35, A-1160 Vienna, Austria
  • 2. Natl Phys Lab, Teddington TW11 0LW, Middx, England
  • 3. SMD, Serv Metrol Sci, B-1000 Brussels, Belgium
  • 4. TUBITAK Ulusal Metrol Enstitusu UME, TR-41470 Gebze, Turkey
  • 5. BIPM, F-92312 Sevres, France

Açıklama

Lasers from three national metrological institutes (NMIs) were compared in 2013 as part of the CCL-K11 ongoing key comparison, initiated by the 13th meeting of the Comite Consultative des Longuers (CCL) in 2007. The absolute frequency of R(127) 11-5 transitions of molecular iodine was measured for these lasers following the technical protocol for CCL-K11. The results of these measurements are compiled in this report. The comparison reports, as communicated by each participant, are included as appendices.