Konferans bildirisi Açık Erişim
Mert Bekir Atsever; Mehmet Hakan Hocaoğlu
{ "conceptdoi": "10.48623/aperta.263792", "conceptrecid": "263792", "created": "2024-03-25T10:45:36.847126+00:00", "doi": "10.48623/aperta.263793", "files": [ { "bucket": "ffc165ba-60b2-4856-8fa1-cdaa94d8dcf6", "checksum": "md5:a19997af4ec8b9971f297ec0ec5f7af9", "key": "Atsever_TESKONGRE_2023.pdf", "links": { "self": "https://aperta.ulakbim.gov.tr/api/files/ffc165ba-60b2-4856-8fa1-cdaa94d8dcf6/Atsever_TESKONGRE_2023.pdf" }, "size": 628363, "type": "pdf" } ], "id": 263793, "links": { "badge": "https://aperta.ulakbim.gov.tr/badge/doi/10.48623/aperta.263793.svg", "bucket": "https://aperta.ulakbim.gov.tr/api/files/ffc165ba-60b2-4856-8fa1-cdaa94d8dcf6", "conceptbadge": "https://aperta.ulakbim.gov.tr/badge/doi/10.48623/aperta.263792.svg", "conceptdoi": "https://doi.org/10.48623/aperta.263792", "doi": "https://doi.org/10.48623/aperta.263793", "html": "https://aperta.ulakbim.gov.tr/record/263793", "latest": "https://aperta.ulakbim.gov.tr/api/records/263793", "latest_html": "https://aperta.ulakbim.gov.tr/record/263793" }, "metadata": { "access_right": "open", "access_right_category": "success", "creators": [ { "affiliation": "Gebze Teknik \u00dcniversitesi", "name": "Mert Bekir Atsever" }, { "affiliation": "\u0130stanbul Ticaret \u00dcniversitesi", "name": "Mehmet Hakan Hocao\u011flu" } ], "description": "<p>Distribution networks play an important role in delivering the generated energy to the end user. It is designed<br>\nto ensure an uninterrupted energy supply. Many undesirable events occur during the operation of distribution<br>\nnetworks. Some of these events are faults. High amplitude currents and/or voltages are observed during faults<br>\nin the distribution network. In both cases, it causes problems in the healthy operation of the distribution<br>\nnetwork. Especially during three-phase faults, high amplitude fault currents create dangerous stresses in the<br>\nsystem elements and surrounding environment. Therefore, the fault must be isolated from the mains selectively<br>\nand as quickly as possible. Optimum overcurrent relay coordination is essential for fast isolation and selective<br>\nprotection. Overcurrent relays are widely used in the detection of three-phase faults. Overcurrent relays<br>\nbasically have two setting parameters. The first tuning parameter is amplitude, and the second is time. Total<br>\nrelay operating times may be improved by optimizing the setting values of the overcurrent relays. For this<br>\nreason, overcurrent relay coordination is designed by researchers as an optimization problem with high<br>\nconstraint functions. In this study, optimum overcurrent relay coordination is realized on a real distribution<br>\nnetwork. Modeling of the 154/33 kV substation was carried out with the data taken from the field. Three-phase<br>\nfault simulations were performed using the EMTP-ATP Draw program. The objective function is constructed<br>\nwith fault current information and relay catalog information. Constraint functions have been added according<br>\nto the network regulation. The objective function was created with both linear and non-linear programming<br>\nmethods. For the solution of both programming methods, the Pathfinder algorithm, which was newly<br>\nintroduced to the literature, was used. It is clearly seen in the results that the Pathfinder algorithm offers a fast<br>\nand optimum solution. Therefore, it has been shown that the Pathfinder algorithm can be used for overcurrent<br>\nrelay coordination.<br>\n </p>", "doi": "10.48623/aperta.263793", "has_grant": false, "license": { "id": "cc-by-nc-4.0" }, "publication_date": "2024-03-25", "related_identifiers": [ { "identifier": "10.48623/aperta.263792", "relation": "isVersionOf", "scheme": "doi" } ], "relations": { "version": [ { "count": 1, "index": 0, "is_last": true, "last_child": { "pid_type": "recid", "pid_value": "263793" }, "parent": { "pid_type": "recid", "pid_value": "263792" } } ] }, "resource_type": { "subtype": "conferencepaper", "title": "Konferans bildirisi", "type": "publication" }, "science_branches": [ "Teknik Bilimler > Elektrik-Elektronik M\u00fchendisli\u011fi > Enerji > G\u00fc\u00e7 Sistemlerinin Analizi" ], "title": "OPTIMAL OVERCURRENT RELAY COORDINATION IN DISTRIBUTION NETWORKS USING PATH FINDER ALGORITHM" }, "owners": [ 735 ], "revision": 1, "stats": { "downloads": 37.0, "unique_downloads": 35.0, "unique_views": 54.0, "version_downloads": 37.0, "version_unique_downloads": 35.0, "version_unique_views": 54.0, "version_views": 70.0, "version_volume": 23249431.0, "views": 70.0, "volume": 23249431.0 }, "updated": "2024-03-25T10:45:36.897646+00:00" }
Tüm sürümler | Bu sürüm | |
---|---|---|
Görüntülenme | 70 | 70 |
İndirme | 37 | 37 |
Veri hacmi | 23.2 MB | 23.2 MB |
Tekil görüntülenme | 54 | 54 |
Tekil indirme | 35 | 35 |