Published January 1, 2010
| Version v1
Journal article
Open
Exergoeconomic analysis of a fluidized-bed coal combustor (FBCC) steam power plant
Creators
- 1. Ege Univ, Mech Engn Sci Branch, Grad Sch Nat & Appl Sci, TR-35100 Izmir, Turkey
- 2. Ege Univ, Fac Engn, Dept Mech Engn, TR-35100 Izmir, Turkey
- 3. Istanbul Tech Univ, Fac Mech Engn, TR-34437 Istanbul, Turkey
Description
Exergoeconomic analysis has been used as a powerful tool to study and optimize various types of energy-related systems. This study deals with an exergoeconomic analysis of an FBCC steam power plant, located in the city of Izmir, Turkey using actual operational data. This plant consists of a ventilation fan (VF), an FBCC, a heat recovery steam generator (HRSG), a cyclone (CY), an economizer (ECO), an aspiration fan (AF), a pump (P) and a chimney (CH) as sub-systems. Quantitative exergy cost balance for each component and the whole FBCC plant is considered. The exergetic efficiency of this plant is calculated to be 20.28% at a steam mass flow rate of 1.861 kg/s. The highest exergy destruction rate occurs in the FBCC with an irreversibility rate of 89.2%, followed by HRSG, VF, ECO, AF, CH and P. The unit exergy cost and exergy cost of steam produced by the FBCC steam plant amount to 17.88 US$/GJ and 93.57 US$/h, respectively. This study demonstrates that exergoeconomic analysis can provide extra information than exergy analysis, while the results obtained from this analysis present cost-based information. (C) 2010 Elsevier Ltd. All rights reserved.
Files
bib-740841b5-1a1e-41e8-818e-2c6c097a0c70.txt
Files
(177 Bytes)
| Name | Size | Download all |
|---|---|---|
|
md5:49a5675eded20e309d7893fddad74939
|
177 Bytes | Preview Download |